{"id":4704,"date":"2026-01-27T12:51:07","date_gmt":"2026-01-27T12:51:07","guid":{"rendered":"https:\/\/www.bunker-bssd.de\/shop\/unkategorisiert\/va-75-ventilation-system\/"},"modified":"2026-01-27T12:51:07","modified_gmt":"2026-01-27T12:51:07","slug":"va-75-ventilation-system","status":"publish","type":"product","link":"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/","title":{"rendered":"VA 75 ventilation system"},"content":{"rendered":"<h3 data-start=\"933\" data-end=\"996\">High-performance breathing air supply for medium-sized shelter rooms<\/h3>\n<p data-start=\"997\" data-end=\"1328\">The <strong data-start=\"1018\" data-end=\"1027\">VA 75 ventilation system<\/strong> is designed for continuous operation in shelters with a medium occupancy level. It ensures a reliable supply of fresh air while simultaneously extracting used indoor air in a controlled manner. This maintains stable oxygen levels and continuously reduces CO\u2082 concentration.  <\/p>\n<p data-start=\"1330\" data-end=\"1673\">In normal operation, ventilation is provided via fresh air intake. In an emergency, the system can be switched to <strong data-start=\"1454\" data-end=\"1474\">gas filtration mode<\/strong> quickly and without tools. The changeover is performed by disconnecting the flexible hoses, enabling effective air filtration in case of chemical, biological, or other hazardous contamination.  <\/p>\n<h3 data-start=\"1680\" data-end=\"1718\">Standards, Certification, and Type Approval<\/h3>\n<p data-start=\"1719\" data-end=\"1956\">All VA 75 ventilation systems supplied by BSSD are manufactured in accordance with the directives of the <strong data-start=\"1800\" data-end=\"1845\">Federal Office for Civil Protection (BABS)<\/strong> and are type-tested by <strong data-start=\"1875\" data-end=\"1942\">LABOR SPIEZ of the Swiss Federal Department of Defence (VBS).<\/strong><\/p>\n<p data-start=\"1958\" data-end=\"1993\"><strong data-start=\"1958\" data-end=\"1993\">Approvals<\/strong> (depending on manufacturer): BZS T 87-003, BZS TE 98-005<\/p>\n<p data-start=\"2030\" data-end=\"2190\">The applicable approval depends on configuration and manufacturer. BSSD ensures that only certified and approved systems are used. <\/p>\n<h3 data-start=\"2197\" data-end=\"2240\">Design, integration, and system compatibility<\/h3>\n<p data-start=\"2241\" data-end=\"2481\">The VA 75 ventilation unit is a compact standalone device suitable for wall mounting inside shelters or installation in separate technical rooms. Multiple units can be operated in parallel if required. <\/p>\n<p data-start=\"2483\" data-end=\"2707\">Connection is made to a shared air intake with <strong data-start=\"2542\" data-end=\"2570\">explosion protection valves<\/strong> and integrated air filter. Within the VA series, installation dimensions are standardized, which simplifies planning, replacement, and system expansion. <\/p>\n<p data-start=\"2709\" data-end=\"2806\">Differences between configurations\u2014depending on the manufacturer\u2014primarily relate to:<\/p>\n<ul data-start=\"2807\" data-end=\"2867\">\n<li data-start=\"2807\" data-end=\"2820\">\n<p data-start=\"2809\" data-end=\"2820\">Pre-filters<\/p>\n<\/li>\n<li data-start=\"2821\" data-end=\"2843\">\n<p data-start=\"2823\" data-end=\"2843\">Airflow measuring tube<\/p>\n<\/li>\n<li data-start=\"2844\" data-end=\"2867\">\n<p data-start=\"2846\" data-end=\"2867\">Gas filter configuration<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"2874\" data-end=\"2917\">Standard Equipment and Emergency Operation<\/h3>\n<p data-start=\"2918\" data-end=\"3070\">The VA 75 ventilation system is designed for both <strong data-start=\"2957\" data-end=\"3026\">electric operation and full manual emergency operatio<\/strong>n. Standard equipment includes: <\/p>\n<ul data-start=\"3072\" data-end=\"3374\">\n<li data-start=\"3072\" data-end=\"3108\">\n<p data-start=\"3074\" data-end=\"3108\">Ventilation unit with electric motor<\/p>\n<\/li>\n<li data-start=\"3109\" data-end=\"3133\">\n<p data-start=\"3111\" data-end=\"3133\">Reduction gearbox<\/p>\n<\/li>\n<li data-start=\"3134\" data-end=\"3176\">\n<p data-start=\"3136\" data-end=\"3176\">Dynamo with sealed 5-watt emergency lamp<\/p>\n<\/li>\n<li data-start=\"3177\" data-end=\"3197\">\n<p data-start=\"3179\" data-end=\"3197\">On\/off switch<\/p>\n<\/li>\n<li data-start=\"3198\" data-end=\"3247\">\n<p data-start=\"3200\" data-end=\"3247\">Attachable hand crank for manual operation<\/p>\n<\/li>\n<li data-start=\"3248\" data-end=\"3288\">\n<p data-start=\"3250\" data-end=\"3288\">Airflow measuring tube with throttle valve<\/p>\n<\/li>\n<li data-start=\"3289\" data-end=\"3334\">\n<p data-start=\"3291\" data-end=\"3334\">Hose pair with coupling and four clamps<\/p>\n<\/li>\n<li data-start=\"3335\" data-end=\"3374\">\n<p data-start=\"3337\" data-end=\"3374\">Operating manual with protective cover <\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3376\" data-end=\"3555\">In case of power failure, manual operation is fully possible. The integrated emergency lighting is powered by the dynamo, ensuring safe operation under outage conditions. <\/p>\n<p data-start=\"3557\" data-end=\"3606\"><strong data-start=\"3557\" data-end=\"3606\">Optional equipment (depending on manufacturer):<\/strong><\/p>\n<ul data-start=\"3607\" data-end=\"3747\">\n<li data-start=\"3607\" data-end=\"3636\">\n<p data-start=\"3609\" data-end=\"3636\">Electric air heater<\/p>\n<\/li>\n<li data-start=\"3637\" data-end=\"3657\">\n<p data-start=\"3639\" data-end=\"3657\">Non-return valve<\/p>\n<\/li>\n<li data-start=\"3658\" data-end=\"3676\">\n<p data-start=\"3660\" data-end=\"3676\">Non-return valve<\/p>\n<\/li>\n<li data-start=\"3677\" data-end=\"3698\">\n<p data-start=\"3679\" data-end=\"3698\">Mounting anchors<\/p>\n<\/li>\n<li data-start=\"3699\" data-end=\"3747\">\n<p data-start=\"3701\" data-end=\"3747\">Alternative voltage and frequency configurations<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"3754\" data-end=\"3787\">Capacity and Applications<\/h3>\n<p data-start=\"3788\" data-end=\"3914\">The <strong data-start=\"3809\" data-end=\"3818\">VA 75<\/strong> ventilation system is designed for shelters with <strong data-start=\"3843\" data-end=\"3870\">14 to 25 occupants<\/strong> and is particularly suitable for:<\/p>\n<ul data-start=\"3916\" data-end=\"4062\">\n<li data-start=\"3916\" data-end=\"3947\">\n<p data-start=\"3918\" data-end=\"3947\">Larger private shelters<\/p>\n<\/li>\n<li data-start=\"3948\" data-end=\"3970\">\n<p data-start=\"3950\" data-end=\"3970\">Multi-family residential buildings<\/p>\n<\/li>\n<li data-start=\"3971\" data-end=\"4018\">\n<p data-start=\"3973\" data-end=\"4018\">Commercial and institutional shelters<\/p>\n<\/li>\n<li data-start=\"4019\" data-end=\"4062\">\n<p data-start=\"4021\" data-end=\"4062\">Medium-sized public shelters<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4064\" data-end=\"4168\">Its higher airflow capacity provides a balanced solution between compact design and performance.<\/p>\n<h3 data-start=\"4175\" data-end=\"4220\">Planning Guidelines and Minimum Requirements<\/h3>\n<ul data-start=\"4222\" data-end=\"4526\">\n<li data-start=\"4222\" data-end=\"4269\">\n<p data-start=\"4224\" data-end=\"4269\">Floor area per occupant: <strong data-start=\"4257\" data-end=\"4267\">\u2265 1 m\u00b2<\/strong><\/p>\n<\/li>\n<li data-start=\"4270\" data-end=\"4314\">\n<p data-start=\"4272\" data-end=\"4314\">Floor area per VA unit: <strong data-start=\"4302\" data-end=\"4312\">\u2265 1 m\u00b2<\/strong><\/p>\n<\/li>\n<li data-start=\"4315\" data-end=\"4359\">\n<p data-start=\"4317\" data-end=\"4359\">Room volume per occupant: <strong data-start=\"4345\" data-end=\"4357\">\u2265 2.5 m\u00b3<\/strong><\/p>\n<\/li>\n<li data-start=\"4360\" data-end=\"4399\">\n<p data-start=\"4362\" data-end=\"4399\">Minimum shelter size: <strong data-start=\"4387\" data-end=\"4397\">\u2265 8 m\u00b2<\/strong><\/p>\n<\/li>\n<li data-start=\"4400\" data-end=\"4438\">\n<p data-start=\"4402\" data-end=\"4438\">Minimum shelter width:<strong data-start=\"4427\" data-end=\"4436\"> 2.0 m<\/strong><\/p>\n<\/li>\n<li data-start=\"4439\" data-end=\"4475\">\n<p data-start=\"4441\" data-end=\"4475\">Minimum shelter height: <strong data-start=\"4464\" data-end=\"4473\">2.0 m<\/strong><\/p>\n<\/li>\n<li data-start=\"4476\" data-end=\"4526\">\n<p data-start=\"4478\" data-end=\"4526\">Maximum occupants per shelter compartment: <strong data-start=\"4518\" data-end=\"4526\">\u2264 50<\/strong> <\/p>\n<\/li>\n<\/ul>\n<p><span style=\"text-align: right; font-size: 14.4px;\">Additional planning must also consider furnishing and protective equipment such as<\/span> <strong style=\"text-align: right; font-size: 14.4px;\" data-start=\"4569\" data-end=\"4619\"><a href=\"https:\/\/www.bunker-bssd.de\/shop\/schutzraumtechnik\/tueren\/panzertuer\/\">blast doors<\/a>, <a href=\"https:\/\/www.bunker-bssd.de\/shop\/schutzraumtechnik\/tueren\/panzerdeckel\/\">protective covers<\/a>, or <span style=\"text-align: right; font-size: 14.4px;\"><a href=\"https:\/\/www.bunker-bssd.de\/shop\/schutzraumtechnik\/sanitaer\/trocken-wc\/\">dry toilets<\/a>.<\/span><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p data-start=\"2683\" data-end=\"2795\"><strong>We are happy to advise you on selecting the appropriate ventilation system as well as on special requirements and accessory solutions.<\/strong><\/p>\n<div id=\"wpcf7-f2321-p741-o1\" class=\"wpcf7 js\" dir=\"ltr\" lang=\"de-DE\" data-wpcf7-id=\"2321\"><\/div>\n<p data-start=\"4500\" data-end=\"4639\"><p class=\"wpcf7-contact-form-not-found\"><strong>Error:<\/strong> Contact form not found.<\/p>\n","protected":false},"excerpt":{"rendered":"<p data-start=\"768\" data-end=\"1162\">The <strong data-start=\"772\" data-end=\"798\">VA 75 ventilation system<\/strong> is a certified shelter air supply unit for <strong data-start=\"843\" data-end=\"865\">14 to 25 occupants<\/strong>. The manufacturer-independent system complies with all <strong data-start=\"925\" data-end=\"945\">BABS directives<\/strong>, is <strong data-start=\"951\" data-end=\"969\">type-tested by VBS<\/strong>, and supports both fresh air and gas filtration operation. With electric and manual emergency modes, it is suitable for both private and public shelters with increased capacity requirements.  <\/p>\n","protected":false},"featured_media":4705,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[194],"product_cat":[307],"product_tag":[],"class_list":["post-4704","product","type-product","status-publish","has-post-thumbnail","product_brand-andair-ag","product_cat-filter-systems-and-valves","product_shipping_class-freight-forwarding-andair-dsz","first","instock","sold-individually","taxable","shipping-taxable","purchasable","product-type-simple","add-to-wishlist-after_add_to_cart"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.9 (Yoast SEO v27.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>VA 75 ventilation system - Bunker BSSD<\/title>\n<meta name=\"description\" content=\"Certified VA 75 shelter ventilation system for 14\u201325 persons. BABS-compliant, VBS type-tested, with gas filtration and emergency operation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"VA 75 ventilation system\" \/>\n<meta property=\"og:description\" content=\"Certified VA 75 shelter ventilation system for 14\u201325 persons. BABS-compliant, VBS type-tested, with gas filtration and emergency operation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/\" \/>\n<meta property=\"og:site_name\" content=\"Bunker BSSD\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.bunker-bssd.de\/wp-content\/uploads\/2026\/01\/Belueftungsanlage-mit-Panzerdeckel.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"2048\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/en\\\/shop\\\/filter-systems-and-valves\\\/va-75-ventilation-system\\\/\",\"url\":\"https:\\\/\\\/www.bunker-bssd.de\\\/en\\\/shop\\\/filter-systems-and-valves\\\/va-75-ventilation-system\\\/\",\"name\":\"VA 75 ventilation system - Bunker BSSD\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/en\\\/shop\\\/filter-systems-and-valves\\\/va-75-ventilation-system\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/en\\\/shop\\\/filter-systems-and-valves\\\/va-75-ventilation-system\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.bunker-bssd.de\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Belueftungsanlage-mit-Panzerdeckel.jpg\",\"datePublished\":\"2026-01-27T12:51:07+00:00\",\"description\":\"Certified VA 75 shelter ventilation system for 14\u201325 persons. BABS-compliant, VBS type-tested, with gas filtration and emergency operation.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/en\\\/shop\\\/filter-systems-and-valves\\\/va-75-ventilation-system\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.bunker-bssd.de\\\/en\\\/shop\\\/filter-systems-and-valves\\\/va-75-ventilation-system\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/en\\\/shop\\\/filter-systems-and-valves\\\/va-75-ventilation-system\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.bunker-bssd.de\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Belueftungsanlage-mit-Panzerdeckel.jpg\",\"contentUrl\":\"https:\\\/\\\/www.bunker-bssd.de\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Belueftungsanlage-mit-Panzerdeckel.jpg\",\"width\":1536,\"height\":2048,\"caption\":\"Bel\u00fcftungsanlage mit Panzerdeckel im Schutzraum installirt\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/en\\\/shop\\\/filter-systems-and-valves\\\/va-75-ventilation-system\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.bunker-bssd.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/www.bunker-bssd.de\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"VA 75 ventilation system\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/#website\",\"url\":\"https:\\\/\\\/www.bunker-bssd.de\\\/\",\"name\":\"BSSD DEFENCE\",\"description\":\"Bunker BSSD Defence\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.bunker-bssd.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/#organization\",\"name\":\"BSSD DEFENCE\",\"url\":\"https:\\\/\\\/www.bunker-bssd.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.bunker-bssd.de\\\/wp-content\\\/uploads\\\/2024\\\/06\\\/bssd-defence_logo.png\",\"contentUrl\":\"https:\\\/\\\/www.bunker-bssd.de\\\/wp-content\\\/uploads\\\/2024\\\/06\\\/bssd-defence_logo.png\",\"width\":4001,\"height\":1263,\"caption\":\"BSSD DEFENCE\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bunker-bssd.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"VA 75 ventilation system - Bunker BSSD","description":"Certified VA 75 shelter ventilation system for 14\u201325 persons. BABS-compliant, VBS type-tested, with gas filtration and emergency operation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/","og_locale":"en_US","og_type":"article","og_title":"VA 75 ventilation system","og_description":"Certified VA 75 shelter ventilation system for 14\u201325 persons. BABS-compliant, VBS type-tested, with gas filtration and emergency operation.","og_url":"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/","og_site_name":"Bunker BSSD","og_image":[{"width":1536,"height":2048,"url":"https:\/\/www.bunker-bssd.de\/wp-content\/uploads\/2026\/01\/Belueftungsanlage-mit-Panzerdeckel.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/","url":"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/","name":"VA 75 ventilation system - Bunker BSSD","isPartOf":{"@id":"https:\/\/www.bunker-bssd.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/#primaryimage"},"image":{"@id":"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/#primaryimage"},"thumbnailUrl":"https:\/\/www.bunker-bssd.de\/wp-content\/uploads\/2026\/01\/Belueftungsanlage-mit-Panzerdeckel.jpg","datePublished":"2026-01-27T12:51:07+00:00","description":"Certified VA 75 shelter ventilation system for 14\u201325 persons. BABS-compliant, VBS type-tested, with gas filtration and emergency operation.","breadcrumb":{"@id":"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/#primaryimage","url":"https:\/\/www.bunker-bssd.de\/wp-content\/uploads\/2026\/01\/Belueftungsanlage-mit-Panzerdeckel.jpg","contentUrl":"https:\/\/www.bunker-bssd.de\/wp-content\/uploads\/2026\/01\/Belueftungsanlage-mit-Panzerdeckel.jpg","width":1536,"height":2048,"caption":"Bel\u00fcftungsanlage mit Panzerdeckel im Schutzraum installirt"},{"@type":"BreadcrumbList","@id":"https:\/\/www.bunker-bssd.de\/en\/shop\/filter-systems-and-valves\/va-75-ventilation-system\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.bunker-bssd.de\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/www.bunker-bssd.de\/shop\/"},{"@type":"ListItem","position":3,"name":"VA 75 ventilation system"}]},{"@type":"WebSite","@id":"https:\/\/www.bunker-bssd.de\/#website","url":"https:\/\/www.bunker-bssd.de\/","name":"BSSD DEFENCE","description":"Bunker BSSD Defence","publisher":{"@id":"https:\/\/www.bunker-bssd.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.bunker-bssd.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.bunker-bssd.de\/#organization","name":"BSSD DEFENCE","url":"https:\/\/www.bunker-bssd.de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.bunker-bssd.de\/#\/schema\/logo\/image\/","url":"https:\/\/www.bunker-bssd.de\/wp-content\/uploads\/2024\/06\/bssd-defence_logo.png","contentUrl":"https:\/\/www.bunker-bssd.de\/wp-content\/uploads\/2024\/06\/bssd-defence_logo.png","width":4001,"height":1263,"caption":"BSSD DEFENCE"},"image":{"@id":"https:\/\/www.bunker-bssd.de\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/product\/4704","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/comments?post=4704"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/media\/4705"}],"wp:attachment":[{"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/media?parent=4704"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/product_brand?post=4704"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/product_cat?post=4704"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/product_tag?post=4704"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}