{"id":7723,"date":"2026-07-27T14:14:17","date_gmt":"2026-07-27T14:14:17","guid":{"rendered":"https:\/\/www.bunker-bssd.de\/shop\/unkategorisiert\/poliprobe-g1-smart-probe\/"},"modified":"2026-08-06T13:06:49","modified_gmt":"2026-08-06T11:06:49","slug":"poliprobe-g1-smart-probe","status":"publish","type":"product","link":"https:\/\/www.bunker-bssd.de\/en\/shop\/personal-protection\/radiation-detection-systems\/poliprobe-g1-smart-probe\/","title":{"rendered":"PoliProbe G1 Smart Probe"},"content":{"rendered":"<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1wqgi93\" data-start=\"800\" data-end=\"888\">Precise Gamma Radiation Monitoring for Shelters, Security, and Monitoring Systems<\/h1>\n<p data-start=\"890\" data-end=\"1275\">The <strong data-start=\"894\" data-end=\"923\">PoliProbe\u2122 G1 Smart Probe<\/strong> is a professional gamma radiation probe designed for continuous measurement of <strong data-start=\"993\" data-end=\"1014\">ambient dose<\/strong> equivalent rate and <strong data-start=\"1023\" data-end=\"1048\">accumulated ambient dose <\/strong>equivalent. Equipped with an energy-compensated <strong data-start=\"1094\" data-end=\"1120\">Geiger-M\u00fcller tube<\/strong>, it delivers reliable measurements across a wide measurement range and is suitable for both fixed and mobile radiation protection applications. <\/p>\n<p data-start=\"1277\" data-end=\"1596\">The Smart Probe has been specifically developed to enhance existing systems with advanced radiation monitoring capabilities or to serve as an external sensor integrated into security, measurement, and monitoring solutions. This makes it ideal for both new installations and the retrofit of existing systems. <\/p>\n<hr data-start=\"1598\" data-end=\"1601\">\n<h2 data-section-id=\"d6dr6f\" data-start=\"1603\" data-end=\"1659\">Designed for Shelters and Critical Infrastructure<\/h2>\n<p data-start=\"1661\" data-end=\"2016\">In bunkers, protective shelters, and other security-critical facilities, continuous monitoring of ambient radiation is an essential part of modern protection concepts. The PoliProbe\u2122 G1 can be deployed as an external gamma probe to continuously monitor radiation levels and transmit data to higher-level monitoring or control systems. <\/p>\n<p data-start=\"2018\" data-end=\"2086\">Its compact design makes it ideal for integration into:<\/p>\n<ul data-start=\"2088\" data-end=\"2286\">\n<li data-section-id=\"1eqdnas\" data-start=\"2088\" data-end=\"2119\">Protective shelters and bunker systems<\/li>\n<li data-section-id=\"1bv4vmx\" data-start=\"2120\" data-end=\"2149\">CBRN and NBC protection systems<\/li>\n<li data-section-id=\"ksrp7a\" data-start=\"2150\" data-end=\"2184\">Fixed radiation monitoring installations<\/li>\n<li data-section-id=\"zzkbx2\" data-start=\"2185\" data-end=\"2208\">Mobile response systems<\/li>\n<li data-section-id=\"17r9t0i\" data-start=\"2209\" data-end=\"2240\">Security and alarm systems<\/li>\n<li data-section-id=\"4dt6u5\" data-start=\"2241\" data-end=\"2286\">Industrial monitoring and measurement solutions<\/li>\n<\/ul>\n<hr data-start=\"2288\" data-end=\"2291\">\n<h2 data-section-id=\"859kgi\" data-start=\"2293\" data-end=\"2309\">Function and Operating Principle<\/h2>\n<p data-start=\"2311\" data-end=\"2666\">The PoliProbe\u2122 G1 continuously measures gamma radiation and calculates both the current ambient dose equivalent rate and the accumulated ambient dose equivalent. An integrated microcontroller processes measurement data in real time using statistical evaluation algorithms to ensure stable and accurate readings, even when radiation levels fluctuate. <\/p>\n<p data-start=\"2668\" data-end=\"2764\">If predefined alarm thresholds are exceeded, the probe immediately alerts users through:<\/p>\n<ul data-start=\"2766\" data-end=\"2818\">\n<li data-section-id=\"mgw2ug\" data-start=\"2766\" data-end=\"2793\">Visual LED indicators<\/li>\n<li data-section-id=\"1hq1nh1\" data-start=\"2794\" data-end=\"2818\">Audible alarm<\/li>\n<\/ul>\n<p data-start=\"2820\" data-end=\"2937\">Measurement data can be transmitted continuously to an external system for real-time monitoring, visualisation, and documentation.<\/p>\n<hr data-start=\"2939\" data-end=\"2942\">\n<h2 data-section-id=\"1dn5oml\" data-start=\"2944\" data-end=\"2966\">Flexible System Integration<\/h2>\n<p data-start=\"2968\" data-end=\"3078\">The PoliProbe\u2122 G1 does not include its own power supply and is designed for operation with external systems.<\/p>\n<p data-start=\"3080\" data-end=\"3143\">It can be connected to:<\/p>\n<ul data-start=\"3145\" data-end=\"3301\">\n<li data-section-id=\"1l4hayx\" data-start=\"3145\" data-end=\"3185\">Industrial automation systems<\/li>\n<li data-section-id=\"1ml1gk2\" data-start=\"3186\" data-end=\"3224\">Security and surveillance systems<\/li>\n<li data-section-id=\"18kont\" data-start=\"3225\" data-end=\"3250\">Polimaster PoliPack BRD<\/li>\n<li data-section-id=\"bof8h3\" data-start=\"3251\" data-end=\"3282\">Custom control systems<\/li>\n<li data-section-id=\"vzyvof\" data-start=\"3283\" data-end=\"3301\">PC workstations<\/li>\n<\/ul>\n<p data-start=\"3303\" data-end=\"3337\">Communication interfaces include:<\/p>\n<ul data-start=\"3339\" data-end=\"3353\">\n<li data-section-id=\"1o4vrg\" data-start=\"3339\" data-end=\"3344\">USB<\/li>\n<li data-section-id=\"79hq8t\" data-start=\"3345\" data-end=\"3353\">RS-485<\/li>\n<\/ul>\n<p data-start=\"3355\" data-end=\"3453\">This enables seamless integration into existing security and monitoring networks.<\/p>\n<hr data-start=\"3455\" data-end=\"3458\">\n<h2 data-section-id=\"17gyd6p\" data-start=\"3460\" data-end=\"3479\">User Software<\/h2>\n<p data-start=\"3481\" data-end=\"3541\">The <strong data-start=\"3509\" data-end=\"3540\">PoliProbe\u2122 G1 User Software<\/strong> is included with the device.<\/p>\n<p data-start=\"3543\" data-end=\"3567\">The software provides:<\/p>\n<ul data-start=\"3569\" data-end=\"3725\">\n<li data-section-id=\"j83d42\" data-start=\"3569\" data-end=\"3597\">Live display of measurement data<\/li>\n<li data-section-id=\"mnpow\" data-start=\"3598\" data-end=\"3633\">Ambient dose rate monitoring<\/li>\n<li data-section-id=\"1yok1rf\" data-start=\"3634\" data-end=\"3668\">Alarm threshold configuration<\/li>\n<li data-section-id=\"1phxvg0\" data-start=\"3669\" data-end=\"3694\">Probe configuration<\/li>\n<li data-section-id=\"pv228k\" data-start=\"3695\" data-end=\"3725\">Convenient data evaluation on a PC<\/li>\n<\/ul>\n<p data-start=\"3727\" data-end=\"3836\">This makes the system equally suitable for permanent installations as well as maintenance and service operations.<\/p>\n<hr data-start=\"3838\" data-end=\"3841\">\n<h2 data-section-id=\"sa37ez\" data-start=\"3843\" data-end=\"3871\">Key Advantages of the PoliProbe\u2122 G1<\/h2>\n<ul data-start=\"3873\" data-end=\"4283\">\n<li data-section-id=\"vrfhgi\" data-start=\"3873\" data-end=\"3918\">Energy-compensated Geiger-M\u00fcller detector<\/li>\n<li data-section-id=\"9t7otr\" data-start=\"3919\" data-end=\"3964\">Measures ambient dose equivalent rate and accumulated ambient dose<\/li>\n<li data-section-id=\"1yxfy6h\" data-start=\"3965\" data-end=\"3990\">Dose rate measurement up to 10 Sv\/h<\/li>\n<li data-section-id=\"1x0jnru\" data-start=\"3991\" data-end=\"4032\">Accumulated dose measurement up to 10 Sv<\/li>\n<li data-section-id=\"1vknrov\" data-start=\"4033\" data-end=\"4068\">Real-time data transmission<\/li>\n<li data-section-id=\"8gzfdu\" data-start=\"4069\" data-end=\"4107\">Easy integration into third-party systems<\/li>\n<li data-section-id=\"clai7a\" data-start=\"4108\" data-end=\"4139\">USB and RS-485 communication interfaces<\/li>\n<li data-section-id=\"1xj7td6\" data-start=\"4140\" data-end=\"4173\">LED and audible alarm functions<\/li>\n<li data-section-id=\"1etos89\" data-start=\"4174\" data-end=\"4197\">Rugged IP65-rated enclosure<\/li>\n<li data-section-id=\"ieotre\" data-start=\"4198\" data-end=\"4216\">Compact design<\/li>\n<li data-section-id=\"eu8076\" data-start=\"4217\" data-end=\"4283\">Reliable operation in demanding environments<\/li>\n<\/ul>\n<hr data-start=\"4285\" data-end=\"4288\">\n<h2 data-section-id=\"zh0546\" data-start=\"4290\" data-end=\"4316\">Typical Areas of Use<\/h2>\n<p data-start=\"4318\" data-end=\"4366\">The PoliProbe\u2122 G1 is ideally suited for:<\/p>\n<ul data-start=\"4368\" data-end=\"4738\">\n<li data-section-id=\"1eqdnas\" data-start=\"4368\" data-end=\"4399\">Protective shelters and bunker systems<\/li>\n<li data-section-id=\"f4r1gv\" data-start=\"4400\" data-end=\"4440\">Government agencies and security organisations<\/li>\n<li data-section-id=\"1b65ul9\" data-start=\"4441\" data-end=\"4461\">Disaster response<\/li>\n<li data-section-id=\"qyugwb\" data-start=\"4462\" data-end=\"4475\">Civil protection<\/li>\n<li data-section-id=\"1m487ld\" data-start=\"4476\" data-end=\"4507\">CBRN and HAZMAT response teams<\/li>\n<li data-section-id=\"1dfnfxl\" data-start=\"4508\" data-end=\"4535\">Police and tactical units<\/li>\n<li data-section-id=\"gwzk3z\" data-start=\"4536\" data-end=\"4549\">Border protection<\/li>\n<li data-section-id=\"ne7c7s\" data-start=\"4550\" data-end=\"4586\">Critical infrastructure operators<\/li>\n<li data-section-id=\"j60ieh\" data-start=\"4587\" data-end=\"4605\">Industrial facilities<\/li>\n<li data-section-id=\"1brhowl\" data-start=\"4606\" data-end=\"4637\">Steel and recycling industries<\/li>\n<li data-section-id=\"1jm0w5w\" data-start=\"4638\" data-end=\"4673\">Waste management and disposal facilities<\/li>\n<li data-section-id=\"lkiqc3\" data-start=\"4674\" data-end=\"4705\">Research laboratories<\/li>\n<li data-section-id=\"1w5zdfs\" data-start=\"4706\" data-end=\"4738\">Fixed-area radiation monitoring<\/li>\n<\/ul>\n<hr data-start=\"4740\" data-end=\"4743\">\n<h2 data-section-id=\"pobtfg\" data-start=\"4745\" data-end=\"4763\">Technical Data<\/h2>\n<p data-section-id=\"89f8fo\" data-start=\"4765\" data-end=\"4777\"><strong>Detector<\/strong>: Energy-compensated Geiger-M\u00fcller tube<\/p>\n<p data-section-id=\"q7gtbq\" data-start=\"4826\" data-end=\"4848\"><strong>Detectable Radiation: <\/strong>Gamma<\/p>\n<p data-section-id=\"j7dtun\" data-start=\"4859\" data-end=\"4892\"><strong>Ambient Dose Rate Range<\/strong>: 1 \u00b5Sv\/h to 10 Sv\/h<\/p>\n<p data-section-id=\"mgmnac\" data-start=\"4917\" data-end=\"4942\"><strong>Ambient Dose Range<\/strong>: 10 \u00b5Sv bis 10 Sv<\/p>\n<p data-section-id=\"xv7pfn\" data-start=\"4964\" data-end=\"4982\"><strong>Energy Range<\/strong><\/p>\n<ul data-start=\"4984\" data-end=\"5054\">\n<li data-section-id=\"13auvk6\" data-start=\"4984\" data-end=\"5002\">30 keV to 3 MeV<\/li>\n<li data-section-id=\"v5f5zi\" data-start=\"5003\" data-end=\"5054\">Protective cap removable for measurements below 48 keV<\/li>\n<\/ul>\n<p data-section-id=\"zgkysr\" data-start=\"5056\" data-end=\"5075\"><strong>Accuracy: <\/strong>\u00b16 % at 300 \u00b5Sv\/h (Reference: \u00b9\u00b3\u2077Cs)<\/p>\n<p data-section-id=\"1gr2hiv\" data-start=\"5117\" data-end=\"5132\"><strong>Alarm Functions: <\/strong>LED indicator and audible alarm<\/p>\n<p data-section-id=\"1ahk4ue\" data-start=\"5169\" data-end=\"5186\"><strong>Communication<\/strong>: USB and RS-485<\/p>\n<p data-section-id=\"75zz39\" data-start=\"5204\" data-end=\"5223\"><strong>Power Supply<\/strong><\/p>\n<ul data-start=\"5225\" data-end=\"5291\">\n<li data-section-id=\"1n5jfl0\" data-start=\"5225\" data-end=\"5238\">3,6\u201316 V DC<\/li>\n<li data-section-id=\"lnx1v3\" data-start=\"5239\" data-end=\"5248\">USB 5 V<\/li>\n<li data-section-id=\"ogycje\" data-start=\"5249\" data-end=\"5258\">12 V DC<\/li>\n<li data-section-id=\"1cqjgdw\" data-start=\"5259\" data-end=\"5291\">optional Li-Ion power supply<\/li>\n<\/ul>\n<p data-section-id=\"gnzap2\" data-start=\"5293\" data-end=\"5309\"><strong>Protection Rating: <\/strong>IP65<\/p>\n<p data-section-id=\"uvm1ru\" data-start=\"5319\" data-end=\"5334\"><strong>Dimensions<\/strong>: 162 \u00d7 \u00d8 40 mm<\/p>\n<p data-section-id=\"1be2tfp\" data-start=\"5353\" data-end=\"5364\"><strong>Weight<\/strong>: 110 g<\/p>\n<p data-section-id=\"1nbq4ur\" data-start=\"5375\" data-end=\"5397\"><strong>Operating Temperature<\/strong>: \u201320 \u00b0C to +50 \u00b0C<\/p>\n<p data-section-id=\"x51fu5\" data-start=\"5420\" data-end=\"5449\"><strong>Relative Humidity<\/strong>: Up to 95 % at 35 \u00b0C<\/p>\n<hr data-start=\"5473\" data-end=\"5476\">\n<h2 data-section-id=\"55v4ht\" data-start=\"5478\" data-end=\"5513\">Why Choose the PoliProbe\u2122 G1?<\/h2>\n<p data-start=\"5515\" data-end=\"6110\">The <strong data-start=\"5519\" data-end=\"5536\">PoliProbe\u2122 G1<\/strong> enhances professional radiation protection and security systems wherever reliable gamma radiation monitoring is required. It is particularly well suited for<strong data-start=\"5684\" data-end=\"5769\"> protective shelters, bunkers, command centres, and critical infrastructure facilities,<\/strong> where it can be easily integrated into existing systems for continuous environmental radiation monitoring. Its rugged construction, simple USB and RS-485 connectivity, and real-time data transmission make it equally suitable for permanent installations and mobile response applications.  <\/p>\n<p data-start=\"5515\" data-end=\"6110\">\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f6374-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"6374\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/en\/wp-json\/wp\/v2\/product\/7723#wpcf7-f6374-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"6374\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.2.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f6374-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/><input type=\"hidden\" name=\"_wpcf7cf_hidden_group_fields\" value=\"[]\" \/><input type=\"hidden\" name=\"_wpcf7cf_hidden_groups\" value=\"[]\" \/><input type=\"hidden\" name=\"_wpcf7cf_visible_groups\" value=\"[]\" \/><input type=\"hidden\" name=\"_wpcf7cf_repeaters\" value=\"[]\" \/><input type=\"hidden\" name=\"_wpcf7cf_steps\" value=\"{}\" \/><input type=\"hidden\" name=\"_wpcf7cf_options\" value=\"{&quot;form_id&quot;:6374,&quot;conditions&quot;:[],&quot;settings&quot;:{&quot;animation&quot;:&quot;yes&quot;,&quot;animation_intime&quot;:200,&quot;animation_outtime&quot;:200,&quot;conditions_ui&quot;:&quot;normal&quot;,&quot;notice_dismissed&quot;:false,&quot;repeater_remove_button&quot;:&quot;bottom&quot;}}\" \/><input type=\"hidden\" name=\"_wpcf7_recaptcha_response\" value=\"\" \/>\n<\/fieldset>\n<p><label> Name *<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" autocomplete=\"name\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span><br \/>\n<\/label>\n<\/p>\n<p><label> Email address *<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" autocomplete=\"email\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span><br \/>\n<\/label>\n<\/p>\n<p><label> Phone number (optional)<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-phone\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-text wpcf7-validates-as-tel\" autocomplete=\"tel\" aria-invalid=\"false\" value=\"\" type=\"tel\" name=\"your-phone\" \/><\/span><br \/>\n<\/label>\n<\/p>\n<p><label> Subject *<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-subject\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"Product Inquiry \/ Consultation\" type=\"text\" name=\"your-subject\" \/><\/span><br \/>\n<\/label>\n<\/p>\n<p><label> Your inquiry<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" name=\"your-message\"><\/textarea><\/span><br \/>\n<\/label>\n<\/p>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Send Inquiry\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>The <strong data-start=\"449\" data-end=\"478\">PoliProbe\u2122 G1 Smart Probe<\/strong> is a compact gamma radiation probe designed for precise measurement of ambient dose equivalent rate and accumulated ambient dose. It has been developed for integration into existing radiation protection and monitoring systems and is ideal for protective shelters, bunkers, government agencies, critical infrastructure, and mobile CBRN operations. <\/p>\n","protected":false},"featured_media":7707,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[351],"product_tag":[],"giftcard-category":[],"class_list":["post-7723","product","type-product","status-publish","has-post-thumbnail","product_cat-radiation-detection-systems","first","instock","taxable","shipping-taxable","product-type-simple","add-to-wishlist-after_add_to_cart"],"_links":{"self":[{"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/product\/7723","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/comments?post=7723"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/media\/7707"}],"wp:attachment":[{"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/media?parent=7723"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/product_brand?post=7723"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/product_cat?post=7723"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/product_tag?post=7723"},{"taxonomy":"giftcard-category","embeddable":true,"href":"https:\/\/www.bunker-bssd.de\/en\/wp-json\/wp\/v2\/giftcard-category?post=7723"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}