Retrofitting Existing Buildings with a Protective Shelter
Protective shelter retrofitting enables an existing room – typically a basement room – to be converted into a fully functional and secure protective shelter. The existing building structure is specifically upgraded and supplemented with modern protective technology to create a reliable retreat location for crisis and emergency situations.
This solution is particularly suitable for owners of existing buildings where a protective shelter was not included during the original construction.
Protection Levels and Possible Applications
Depending on the configuration, a retrofitted protective shelter can provide protection against:
-
Nuclear, biological, and chemical (NBC) hazards
-
Radioactive contamination
-
Fire exposure and smoke gases
-
Explosions and pressure waves
-
Break-ins, violent attacks, terrorism, and civil unrest
-
Natural disasters and industrial or power plant accidents
Structural Requirements and Recommended Rooms
For professional retrofitting, the following basic requirements apply:
-
Location preferably in a corner of the building
-
No or only minimal openings to the outside
-
Recommended room size: 15–30 m²
-
Clear room height of at least 1.95 m
-
No chimney, gas, or heating pipe penetrations
-
No fire or explosion hazards in the immediate vicinity
Existing professionally constructed masonry and load-bearing interior plaster can generally remain in place. If required, existing walls can be additionally reinforced.
Construction and Structural Requirements
-
Ceilings above the protective shelter including screed: minimum 15 cm thickness
-
Exterior walls below ground level: ≥ 350 kg/m²
-
Exterior walls above ground level: ≥ 1,000 kg/m²
-
Interior walls adjacent to openings: ≥ 750 kg/m²
-
Basement windows in the shelter area can be bricked up or fitted with a custom-made hatch upon request.
- The basement window can serve as an emergency exit.
NBC Air Filtration and Pressure System
A key element of protective shelter retrofitting is the controlled air supply system:
-
NBC gas filtration system
-
Filtration of nuclear, biological, and chemical contaminants
-
Creation of controlled positive pressure inside the shelter
-
Explosion protection valves and gas flaps for pressure regulation
This ensures a reliable supply of breathable air even when the outside air is contaminated.
Standard Safety Equipment
-
Robust pressure door or armored door
Usage Concept
The protective shelter is designed for multiple uses:
-
Everyday use, for example as storage or technical space
-
Emergency use during crises and disasters as a protected sanctuary area
You can get an insight into the construction and equipment concept in our video: https://www.youtube.com/shorts/o7F3MNg7zQ4
Planning and Implementation
Before implementation, our specialists assess:
-
Existing structural conditions
-
Static requirements
-
Load-bearing capacity of walls and ceilings
-
Technical feasibility
Planning is always carried out individually and specifically for each property to ensure a safe, standards-compliant, and technically reliable retrofit solution.