Reliable Heating for Shelters and Bunker Facilities
The air heater for the VA75 and VA150 gas filtration systems was specifically designed for use in shelters, bunkers, and security-critical facilities. It ensures reliable and uniform heating of the supply air, even under shielded conditions and during continuous operation.
This robust heating unit supports the functionality of the shelter ventilation system and contributes significantly to the operational safety, usability, and comfort of protected spaces.
Robust design for use in shelters
The air heater consists of a durable steel tube with an inner diameter of 125 mm and is designed to provide uniform heat distribution within the airflow.
The sheet-steel connection housing, mounted on one side, enables a safe, code-compliant connection to existing gas filter and ventilation systems.
The design is intended for long-term use in safety-critical infrastructure.
Precise temperature control and high operational reliability
To ensure controlled and safe heating operation, the air heater is equipped with the following safety features:
-
Regulating Safety Thermostat, Externally Operated
-
Infinitely adjustable from 30 °C to 110 °C
-
-
Over-temperature limiter set at 130 °C for additional protection
-
Backflow valve (NW 125 mm) in the lower section
-
Prevents heat from flowing back into the fan
-
Protects the entire ventilation system from thermal stress
-
These components ensure reliable operation even during continuous or emergency operation.
Technical Specifications – Electric Air Heaters
1.5 kW model
-
Suitable for airflow rates of 75 m³/h and 150 m³/h
-
Rated voltage: 3 × 400 V
-
Rated current: 2.2 A
-
Protection Class: IP20
-
Overall length: 500 mm
3.0 kW model
-
Suitable for airflow rates of 150 m³/h and 300 m³/h
-
Rated voltage: 3 × 400 V
-
Rated current: 4.4 A
-
Protection Class: IP20
-
Overall length: 500 mm
-
Weight: 3.45 kg
Assembly and Integration
Installation is performed by placing the unit on the corresponding fan (VA 40 / VA 75 / VA 150).
The unit is secured by screwing or riveting.
Recommended mounting hardware:
-
Special Clamps
-
Mounting Bracket
-
Anchor
-
Rivets or screws
The air heater can be operated with direct exhaust or in conjunction with an air distribution duct and can be easily integrated into existing shelter designs.
Operational Benefits
-
Reliable Heating for Shelters and Bunker Facilities
-
Compatible with VA75 and VA150 gas filtration systems
-
High operational reliability thanks to multi-stage temperature monitoring
-
Rugged, durable design for safety-critical environments
-
Suitable for continuous operation and emergency situations
Individual consultation
Our experts will help you choose the right air heater for your shelter system. Contact us now to discuss the best solution for your project.











Reviews